It is widely applied in charging and discharging each kind of battery and accumulator.
Reference Standards
Model |
FNTH180-2-20 |
FNTH180-2-40 |
||
(mm) Internal size |
W |
600 |
||
H |
500 |
|||
D |
600 |
|||
(mm) External size(excluding projecting portion) |
W |
830 |
||
H |
2023 |
|||
D |
2139 |
|||
Temperature range |
-20℃~+150℃ |
-40℃~+150℃ |
||
Humidity range |
20%RH~98%RH/(20~85℃) |
|||
Temperaure fluctuation |
±0.5℃ |
|||
Temperature dviation |
±1.5℃ |
|||
Humidity deviation |
±3.0%RH(≧ 75%); ±5.0%RH(≦ 75%) |
|||
Warm-up time |
+20℃~+150℃ |
+20℃~+150℃ |
||
≦ 50MIN |
≦ 50MIN |
|||
Cooling time |
+20℃~-20℃ |
+20℃~-40℃ |
||
≦ 60MIN |
≦ 70MIN |
|||
Temperature and humidity regulating mode |
Balance temperature regulating(humidity regulating)mode |
|||
Temperature of using environment |
+5℃~+35℃ |
|||
Material |
Shell |
Double-side electrolysis plank and spraying plastics |
||
Inner shell |
Stainless steel plate SUS304/2B |
|||
Thermal insulation |
Polyurethane foam+fiberboard |
|||
Regulator |
Heater |
Nicochrome fin heating tube |
||
Humidifier |
Stainless steel armored heater(humidifying the water pond) |
|||
Fan |
Centrifugal fan |
|||
Refrigerating fluid |
Mechanical compressor |
|||
Refrigerating fluid |
R404a |
|||
Refrigerating mode |
Mechanical compression refrigeration (air cooling or water cooling) |
|||
Controller |
Display |
7.0 inch, TFT color LCD display |
||
Operation mode |
Program operation, fixed value operation |
|||
Setting mode |
Chinese menu, input by touch screen |
|||
Progarm capacity |
Number of editable program: 99 maximum; step: 999 steps; cycle number: 99 maximum |
|||
Setting mode |
Temperature: adjust according to the temperature range of the equipment; humidity: 0%RH-100%RH(such as humidity function of equipment) |
|||
Display resolution |
Temperature: 0.01℃; time: 0.1min; humidity; 0.1%RH(temperature and humidity test equipment) |
|||
Input |
Thermal resistance and thermonuclear |
|||
Communication function(purchasing) |
RS-485 interface with local and remote communication function, monitoring software, RS-485/RS-232 convertor, one COM interface and one USB interface occupying PC computer, connect 16 sets of equipment at most; and the maximum accumulated lenqth of the cable is 800M |
|||
Control mode |
PID Anti-integration saturation-PID |
|||
Curve recording function |
RAM with battery protection: it can save the setting value, sampling value and sampling time of equipment; and the maximum recording time is 350 days(when the sampling period is 1.5min) |
|||
USB function |
It is equipped with one U-disk special for PC computer(applicable for simple and complex Chinese, English WINDOWS operation system); the test program is compiled by PC software and saved in U-disk; and then the test program is tuned out from the U-disk and saved in the controller; or the controller can be saved in U-disk; and then it is saved in Pccomputer to be analyzed and managed. The record data of the test curve recorded in the controller can be saved to U-disk; the test data/curve is directly displayed and printed by special software of PC computer; and the data is converted into format file. The recording data of the controller is as follows; two-circuit temperature-setting temperature and actually measured emperature; two-circuit humidity-setting humidity and actually measured humidity. |
|||
Auxiliary function |
Fault alarm and reason, treatment prompt function, power failure protection function, and upper and lower temperature limit protection function; Calendar timing function(automatic starting or automatic stopping); self-diagnostic function |
|||
Water supply mode |
Supply water by water pump |
|||
Water storage tank |
Handheld auxiliary water tank |
|||
Water quality |
Resistance rate500Ωm |
|||
Power |
AC380V±10%V 50HZ |
|||
Standard configuration |
One observation window(transparent electrothermal film center control glass), one Ф50mm of cable hole in the right and left; two sets of sample racks, floodlight, time accumulator(internal), four foot wheels, one power cable(3m long), one RS-485/232 interface, one control terminal of test power, one USB interface and one U-disk. |
|||
Safety device |
Residual-current circuit breaker, dry burning protector(for damp and heat only), water system protection device(for damp and heat only), overhead protection of fan motor, fuse, overload shor circuit protector of control loop, temperature limiting protector, under-voltage protector of cooling water(for water cooling type only), over-pressure, over-current and overheat protection for compressor, phase sequence protection and over-current protection of condensate fan(for air cooling). |
Let's get to know each other
Would you like to purchase one of our products, do you have any question about a product or about services or do you need further information?
We are always just one phone call away or you can send us a message here