Specially designed to be double-stacked on the floor or located on the lab benches for space saving with optional accessories
Structural Functional Features
Use Convenience Features
Outstanding Safety
Smart Self-diagnosis
Real-time self-diagnostics to check equipment for abnormal conditions.
Model | ISS-3075 | ISS-3075R | ISS-4075 | ISS-4075R | |||||
---|---|---|---|---|---|---|---|---|---|
Temperature | Range (℃ / ℉)1) | Amb. +5 to 80
/ Amb. +9 to 176 |
Amb. -20 (Min. 4) to 80
/Amb. -36 (Min. 7.2) to 176 |
Amb. +5 to 80
/Amb. +9 to 176 |
Amb. -20 (Min. 4) to 80
/Amb. -36 (Min. 7.2) to 176 |
||||
Fluctuation at 37℃ in flask
(±℃ / ℉) |
0.1 / 0.18 | ||||||||
Variation at 37℃ in flask
(±℃ / ℉) |
0.5 / 0.90 | ||||||||
Refrigerator (Hp) | - | 1/6Hp | - | 1/6Hp | |||||
Shaking system | Motion type | Orbital | |||||||
Amplitude size (mm / inch, dia.) | 19.1 / 0.75 | ||||||||
Speed range (rpm) | 20 to 500 (stackable : 20 to 250) | ||||||||
Speed stability2)(rpm, %) | ±1 | ||||||||
Timer (count-down) | 999 hr 59 min. | ||||||||
Max. Speed per permissible Load (rpm) | 500 (max.10kg / 22.0 lbs)
400 (max.15kg / 33.1 lbs) 250 (max.15kg / 33.1 lbs) - (stacked) |
500 (max.10kg / 22.0 lbs)
400 (max.21kg / 46.3 lbs) 250 (max.21kg / 46.3 lbs) - (stacked) |
|||||||
Dimension | Volume (L / cu ft) | 80 / 2.8 | 150 / 5.3 | ||||||
Platform (W×D, mm / inch) | 350×350 / 13.8x13.8 | 450×450 / 17.7×17.7 | |||||||
Interior (W×D×H, mm / inch) | 440×440×418 / 17.3×17.3×16.5 | 540×540×518 / 21.3×21.3×20.4 | |||||||
Exterior (W×D×H, mm / inch) | 578×815×854 / 22.8x32.1x33.6 | 678×895×934 / 26.7x35.2x36.8 | |||||||
Shelves (Standard / Max) | 2 / 8 | 2 / 11 | |||||||
Net weight (kg / Ibs) | 153 / 337.3 | 160 / 352.7 | 183 / 403.4 | 190 / 418.9 | |||||
Electrical requirements (230V, 50/60Hz, A ) | 6.2 | 7.9 | 6.2 | 7.9 | |||||
Cat. No. | AAH23432K | AAH23532K | AAH23632K | AAH23732K | |||||
Electrical requirements (120V, 60Hz, A) | 9.5 | 13 | 9.5 | 13 | |||||
Cat. No. | AAH23415U | AAH23515U | AAH23615U | AAH23715U |
1) The temperature control range of the IST-3075 and IST-4075 models are from 5°C above the ambient temperature of the equipment. (15°C to 40°C) to 80°C.
The temperature control range of the IST-3075R and IST-4075R models are from 15°C below the ambient temperature (18°C to 35°C) of the device to 80°C. (However, the lowest control temperature is 15°C)
2) Actual rpm allowable error for set rpm is ±1rpm if setting is less than 100rpm, ±1% if setting is higher than 100rpm.
Let's get to know each other
Would you like to purchase one of our products, do you have any question about a product or about services or do you need further information?
We are always just one phone call away or you can send us a message here